DTS Instrument Box Object
The instrument box used for distributed temperature surveys
A name for the instrument box. This can be used to access
the instrument box.
The ultimate manufacturer of the instrument box.
The date the manufacturing of the instrument box was completed.
The type of instrument box used.
An identification tag for the instrument box.
A serial number is a type of identification tag however
some tags contain many pieces of information.
This structure just identifies the tag and does not describe the contents.
The version of the software installed in the instrument box.
Information about the calibration of the instrument box that
was performed. This includes factory calibrations before shipping, and bench
calibrations. This does not include calibrations made in preparation for
taking measurements.
Near distance of the oven from the beginning of the fiber.
Far distance of the oven from the beginning of the fiber.
The temperature of the oven.
The cable used to test the instrument box.
The offset setting applied to the instrument box based on
the factory or bench calibration.
The power loss over the length of the cable.
Additional parameters to define the instrument box as a
piece of equipment. These should not be parameters to define the installation
or use of the box in the wellbore, or other system. This element should be used
only if an appropriate parameter is not available as an element, or in the
calibration operation.
Unique identifier for the instrument box.