root / projects / DailyProductionReport_1.0 / XML / Version1.0 / WITSML131 / grp_dtsInstalledSystem.xsd @ 16

Revision 16, 6.3 kB (checked in by ryland, 15 years ago)
Line 
1<?xml version="1.0" encoding="UTF-8"?>
2<xsd:schema
3        elementFormDefault="qualified"
4        attributeFormDefault="unqualified"
5        targetNamespace="http://www.witsml.org/schemas/131"
6        xmlns:witsml="http://www.witsml.org/schemas/131"
7        xmlns:xsd="http://www.w3.org/2001/XMLSchema"
8        version="1.3.1">
9
10        <!--                                                         -->
11        <!-- POSC License Agreement
12        This file is distributed under the POSC License Agreement at
13        http://www.posc.org/about/license.shtml.
14        Use of this file constitutes agreement with the POSC License Agreement.
15        -->
16        <!--                                                         -->
17        <xsd:include schemaLocation="cs_fiberInformation.xsd"/>
18        <xsd:include schemaLocation="cs_boxInformation.xsd"/>
19        <xsd:include schemaLocation="cs_fiberInstalledPoints.xsd"/>
20        <xsd:include schemaLocation="cs_fiberEndPoint.xsd"/>
21        <xsd:include schemaLocation="cs_otdr.xsd"/>
22        <xsd:include schemaLocation="cs_pumpActivity.xsd"/>
23        <xsd:include schemaLocation="cs_calibration.xsd"/>
24        <!--                                                         -->
25        <xsd:annotation>
26                <xsd:documentation>DTS Installed System Type</xsd:documentation>
27        </xsd:annotation>
28        <!--                                                         -->
29        <xsd:group name="grp_dtsInstalledSystem">
30                <xsd:annotation>
31                        <xsd:documentation>The optical fiber is installed in a wellbore and attached to an
32                        instrument box. Calibrations are performed. In general, this should be a subelement of
33                        a DTS object.</xsd:documentation>
34                </xsd:annotation>
35                <xsd:sequence>
36                        <xsd:element name="isPlanned" type="witsml:logicalBoolean" minOccurs="0" maxOccurs="1">
37                                <xsd:annotation>
38                                        <xsd:documentation>Is this a planned installation in a well, or has the
39                                        installation already occurred. Note that the default value is 'false',
40                                        which states that this is an actual installation.</xsd:documentation>
41                                </xsd:annotation>
42                        </xsd:element>
43                        <xsd:element name="fiberInformation" type="witsml:cs_fiberInformation" minOccurs="0" maxOccurs="1">
44                                <xsd:annotation>
45                                        <xsd:documentation>Information about the fiber used, and its installation.</xsd:documentation>
46                                </xsd:annotation>
47                        </xsd:element>
48                        <xsd:element name="instrumentBoxInformation" type="witsml:cs_boxInformation" minOccurs="0" maxOccurs="1">
49                                <xsd:annotation>
50                                        <xsd:documentation>Information about the instrument box used, and its installation.</xsd:documentation>
51                                </xsd:annotation>
52                        </xsd:element>
53                        <xsd:element name="fiberConfiguration" type="witsml:kindString" minOccurs="0" maxOccurs="1">
54                                <xsd:annotation>
55                                        <xsd:documentation>The configuration of the fiber installation. Example values
56                                        would be linear, linear with gauge, J, U.</xsd:documentation>
57                                </xsd:annotation>
58                        </xsd:element>
59                        <xsd:element name="fiberEndPoint" type="witsml:cs_fiberEndPoint" minOccurs="0" maxOccurs="2">
60                                <xsd:annotation>
61                                        <xsd:documentation>A fiber installed with a "U" configuration will have two ends
62                                        available for hookup to an instrument box. In order to record which end is
63                                        cabled to the instrument box on a particular measurement run, it is necessary
64                                        to identify the two ends. This complex type allows a name and description for
65                                        each end, so that it may be identified in a later use. This may also be useful
66                                        when multiple fibers in multiple wellbores converge at the same wellhead.</xsd:documentation>
67                                </xsd:annotation>
68                        </xsd:element>
69                        <xsd:element name="fiberLength" type="witsml:lengthMeasure" minOccurs="0" maxOccurs="1">
70                                <xsd:annotation>
71                                        <xsd:documentation>The length of the fiber installed in the wellbore.</xsd:documentation>
72                                </xsd:annotation>
73                        </xsd:element>
74                        <xsd:element name="wellboreFiberSchematic" type="witsml:cs_fiberInstalledPoints" minOccurs="0" maxOccurs="1">
75                                <xsd:annotation>
76                                        <xsd:documentation>A table of values along the length along the fiber.</xsd:documentation>
77                                </xsd:annotation>
78                        </xsd:element>
79                        <xsd:element name="opticalBudget" type="witsml:generalMeasureType" minOccurs="0" maxOccurs="1">
80                                <xsd:annotation>
81                                        <xsd:documentation>Total light budget available for the installation. This is
82                                        generally measured in decibels, and indicates the total power loss for two-way
83                                        travel of the light in the installed fiber.</xsd:documentation>
84                                </xsd:annotation>
85                        </xsd:element>
86                        <xsd:element name="pumpActivity" type="witsml:cs_pumpActivity" minOccurs="0" maxOccurs="1">
87                                <xsd:annotation>
88                                        <xsd:documentation>The activity of pumping the fiber downhole</xsd:documentation>
89                                </xsd:annotation>
90                        </xsd:element>
91                        <xsd:element name="otdrInstallationTest" type="witsml:cs_otdr" minOccurs="0" maxOccurs="unbounded">
92                                <xsd:annotation>
93                                        <xsd:documentation>This captures the data from the pre-installation and post-installation
94                                        OTDR tests run on the fiber. A standard quality control program would include these
95                                        two, but the schema allows for more than two if additional runs associated with the
96                                        installation of the fiber are performed. OTDR runs associated with a measurement are
97                                        given as a child of the measurementInformation element.</xsd:documentation>
98                                </xsd:annotation>
99                        </xsd:element>
100                        <xsd:element name="installationCalibration" type="witsml:cs_calibration" minOccurs="0" maxOccurs="unbounded">
101                                <xsd:annotation>
102                                        <xsd:documentation>Any calibration other than the ones explicitly given may be
103                                        recorded here. This is a general calibration type, which is populated with name/value pairs.</xsd:documentation>
104                                </xsd:annotation>
105                        </xsd:element>
106                        <xsd:element name="basedOnInstalledFiber" type="witsml:refNameString" minOccurs="0" maxOccurs="1">
107                                <xsd:annotation>
108                                        <xsd:documentation>If an instrument box is changed, for example, but the
109                                        fiber remains the same, this instance of installed fiber is given to record
110                                        that change. This element refers to a previous installed fiber, on which
111                                        this one is based. For example, the wellboreFiberSchematic is unchanged, and
112                                        may be obtained from the previous instance of installed fiber that is
113                                        referenced here.</xsd:documentation>
114                                </xsd:annotation>
115                        </xsd:element>
116                </xsd:sequence>
117        </xsd:group>
118        <!--                                                         -->
119</xsd:schema>
Note: See TracBrowser for help on using the browser.