1 | <?xml version="1.0" encoding="UTF-8"?> |
---|
2 | <?xml-stylesheet type="text/xsl" href="../stylesheets/dtsInstalledSystem.xsl"?> |
---|
3 | |
---|
4 | <dtsInstalledSystems |
---|
5 | xmlns="http://www.witsml.org/schemas/131" |
---|
6 | xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" |
---|
7 | xsi:schemaLocation="http://www.witsml.org/schemas/131 ../obj_dtsInstalledSystem.xsd" |
---|
8 | version="1.3.1.1"> |
---|
9 | |
---|
10 | <documentInfo> |
---|
11 | <DocumentName>dtsInstalledSystem</DocumentName> |
---|
12 | <FileCreationInformation> |
---|
13 | <FileCreationDate>2005-06-12T13:13:13.22-05:00</FileCreationDate> |
---|
14 | <FileCreator>Jack's installation team</FileCreator> |
---|
15 | </FileCreationInformation> |
---|
16 | </documentInfo> |
---|
17 | |
---|
18 | <dtsInstalledSystem uidWell="D88CA733F" uidWellbore="82996A3B" uid="1FO19-120050992-1"> |
---|
19 | <nameWell>1FO19</nameWell> |
---|
20 | <nameWellbore>1FO19-1</nameWellbore> |
---|
21 | <name>Wellbore 1FO19-1 installation 9Jun2005</name> |
---|
22 | <isPlanned>false</isPlanned> |
---|
23 | <fiberInformation> |
---|
24 | <installationDate>2005-06-02T00:00:00.00-05:00</installationDate> |
---|
25 | <installationCompany>Mitey Fine DTSers</installationCompany> |
---|
26 | <deInstallationDate>2006-12-17T09:30:47-05:00</deInstallationDate> |
---|
27 | <fiber uid="f1"> |
---|
28 | <name>Example Fiber One</name> |
---|
29 | <mode>singlemode</mode> |
---|
30 | <type classType="size rank">50/125</type> |
---|
31 | <type classType="flexibility">flexible</type> |
---|
32 | <coating>gold</coating> |
---|
33 | <jacket>hytrel</jacket> |
---|
34 | <coreDiameter uom="um">50.</coreDiameter> |
---|
35 | <outsideDiameter uom="um">900</outsideDiameter> |
---|
36 | <refractiveIndex uid="rfin1"> |
---|
37 | <value>1.4976</value> |
---|
38 | <wavelength uom="nm">482</wavelength> |
---|
39 | </refractiveIndex> |
---|
40 | <refractiveIndex uid="rfin2"> |
---|
41 | <value>1.4968</value> |
---|
42 | <wavelength uom="nm">615</wavelength> |
---|
43 | </refractiveIndex> |
---|
44 | <oneWayLoss uid="owl1"> |
---|
45 | <value uom="dB/km">.18</value> |
---|
46 | <wavelength uom="nm">482</wavelength> |
---|
47 | </oneWayLoss> |
---|
48 | <parameter index="1" name="extra parameter 1" uom="cm" description="Some length parameter">16.2</parameter> |
---|
49 | <parameter index="1" name="extra parameter 2" description="glossy scale">shiny and bright</parameter> |
---|
50 | <parameter index="1" name="extra parameter 3" uom="s" description="Some time parameter">.234</parameter> |
---|
51 | <spoolNumberTag>A16677</spoolNumberTag> |
---|
52 | <spoolLength uom="m">6000</spoolLength> |
---|
53 | <supplyDate>2001-12-17T09:30:47-05:00</supplyDate> |
---|
54 | <supplier>Corning</supplier> |
---|
55 | <supplierModelNumber>T130XL</supplierModelNumber> |
---|
56 | <factoryCalibration uid="fcal1"> |
---|
57 | <dTimCalibration>1967-08-13</dTimCalibration> |
---|
58 | <calibratedBy>Joe Belatoni</calibratedBy> |
---|
59 | <calibrationProtocol>standard bench check</calibrationProtocol> |
---|
60 | <parameter uom="dB" name="calibration parameter 1">15.2</parameter> |
---|
61 | <remarks>No calibration problems occurred.</remarks> |
---|
62 | </factoryCalibration> |
---|
63 | <installationHistory>dtsInstA</installationHistory> |
---|
64 | </fiber> |
---|
65 | </fiberInformation> |
---|
66 | <instrumentBoxInformation uid="x"> |
---|
67 | <installationDate>2001-12-17T09:30:47-05:00</installationDate> |
---|
68 | <installationCompany>String</installationCompany> |
---|
69 | <deInstallationDate>2001-12-17T09:30:47-05:00</deInstallationDate> |
---|
70 | <instrumentBox uid="box1"> |
---|
71 | <name>Example Instrument Box 1</name> |
---|
72 | <manufacturer>Yorick</manufacturer> |
---|
73 | <manufacturingDate>2001-12-17</manufacturingDate> |
---|
74 | <type>DTS800-M12</type> |
---|
75 | <nameTag> |
---|
76 | <name>123456789</name> |
---|
77 | <numberingScheme>serial number</numberingScheme> |
---|
78 | </nameTag> |
---|
79 | <softwareVersion>1.2</softwareVersion> |
---|
80 | <factoryCalibration uid="boxcal1"> |
---|
81 | <dTimCalibration>1967-08-13</dTimCalibration> |
---|
82 | <calibratedBy>Groener Vassar</calibratedBy> |
---|
83 | <calibrationProtocol>IEEE 7.3</calibrationProtocol> |
---|
84 | <parameter uom="mm" name="parameter one">2.77</parameter> |
---|
85 | <parameter uom="ms" name="parameter two">881</parameter> |
---|
86 | <parameter uom="ubar" name="parameter three">55.8</parameter> |
---|
87 | <remarks>Bench calibration to set internal box settings</remarks> |
---|
88 | <offsetTemperatureCalibration uom="degC">2.8</offsetTemperatureCalibration> |
---|
89 | <slopeCalibration uom="degC/km">1.88</slopeCalibration> |
---|
90 | </factoryCalibration> |
---|
91 | <internalOvenLocationNear uom="m">35</internalOvenLocationNear> |
---|
92 | <internalOvenLocationFar uom="m">85</internalOvenLocationFar> |
---|
93 | <ovenSetPoint uom="degC">48.3</ovenSetPoint> |
---|
94 | <testCable>AXBZ123</testCable> |
---|
95 | <offset>2.8 degC</offset> |
---|
96 | <differentialLossSetting uom="db/km">.345</differentialLossSetting> |
---|
97 | <parameter index="1" name="parameter three" uom="lbf" description="Weight of the instrument box">27.2</parameter> |
---|
98 | <parameter index="1" name="parameter four" uom="cm" description="Height of the instrument box">66</parameter> |
---|
99 | </instrumentBox> |
---|
100 | </instrumentBoxInformation> |
---|
101 | <fiberConfiguration>U</fiberConfiguration> |
---|
102 | <fiberEndPoint uid="A6"> |
---|
103 | <name>C-1</name> |
---|
104 | <description>Port 1 connector box. Pumping end of the U</description> |
---|
105 | </fiberEndPoint> |
---|
106 | <fiberEndPoint uid="A7"> |
---|
107 | <name>C-2</name> |
---|
108 | <description>Port 2 connector box. End pumped up the hole</description> |
---|
109 | </fiberEndPoint> |
---|
110 | <fiberLength uom="m">9260</fiberLength> |
---|
111 | <wellboreFiberSchematic> |
---|
112 | <installedPoint uid="I1"> |
---|
113 | <lengthAlongFiber uom="m">87</lengthAlongFiber> |
---|
114 | <type>oven exit point</type> |
---|
115 | </installedPoint> |
---|
116 | <installedPoint uid="I2"> |
---|
117 | <lengthAlongFiber uom="m">143</lengthAlongFiber> |
---|
118 | <type>wellhead junction box</type> |
---|
119 | </installedPoint> |
---|
120 | <installedPoint uid="I3"> |
---|
121 | <md uom="m" datum="GL">4548</md> |
---|
122 | <lengthAlongFiber uom="m">4692</lengthAlongFiber> |
---|
123 | <type>turn around point</type> |
---|
124 | </installedPoint> |
---|
125 | <installedPoint uid="I4"> |
---|
126 | <lengthAlongFiber uom="m">9233</lengthAlongFiber> |
---|
127 | <type>wellhead junction box</type> |
---|
128 | </installedPoint> |
---|
129 | </wellboreFiberSchematic> |
---|
130 | <opticalBudget uom="dB">3</opticalBudget> |
---|
131 | <pumpActivity uid="p1"> |
---|
132 | <name>Pumping6</name> |
---|
133 | <installedFiber uidRef="92AB8224">Example Fiber One</installedFiber> |
---|
134 | <pumpingDate>2005-06-12T09:30:47-05:00</pumpingDate> |
---|
135 | <engineerName>Bob Robertson</engineerName> |
---|
136 | <serviceCompany>Our Pumping Group</serviceCompany> |
---|
137 | <pumpFluidType>oil</pumpFluidType> |
---|
138 | <controlLineFluid>oil</controlLineFluid> |
---|
139 | <pumpDirection>down</pumpDirection> |
---|
140 | <fiberEndSeal>polygrip</fiberEndSeal> |
---|
141 | <cableMeterType>line</cableMeterType> |
---|
142 | <cableMeterSerialNumber>123456789</cableMeterSerialNumber> |
---|
143 | <cableMeterCalibrationDate>2003-12-02</cableMeterCalibrationDate> |
---|
144 | <wasDriftRunPerformed>true</wasDriftRunPerformed> |
---|
145 | <excessFiberRecovered uom="m">32</excessFiberRecovered> |
---|
146 | <pumpLog> |
---|
147 | <tableRow uid="PR1"> |
---|
148 | <cableSpeed uom="m/s">12</cableSpeed> |
---|
149 | <fiberPumpedLength uom="m">9130</fiberPumpedLength> |
---|
150 | <pumpPressure uom="kPa">1600</pumpPressure> |
---|
151 | <pumpFluid>oil</pumpFluid> |
---|
152 | <temperatureIn uom="degC">26.3</temperatureIn> |
---|
153 | <temperatureOut uom="degC">83.5</temperatureOut> |
---|
154 | <remarks>Remarkable</remarks> |
---|
155 | </tableRow> |
---|
156 | </pumpLog> |
---|
157 | </pumpActivity> |
---|
158 | <otdrInstallationTest uid="otdr1"> |
---|
159 | <reasonForRun>pre-installation</reasonForRun> |
---|
160 | <dTimRun>2005-05-22T00:00:00-05:00</dTimRun> |
---|
161 | <dataInWellLog>otdr20050522</dataInWellLog> |
---|
162 | <fiberEndConncected>C-1</fiberEndConncected> |
---|
163 | <comment>Standard OTDR test run</comment> |
---|
164 | </otdrInstallationTest> |
---|
165 | <installationCalibration uid="instcal1"> |
---|
166 | <dTimCalibration>1967-08-13</dTimCalibration> |
---|
167 | <calibratedBy>Jim</calibratedBy> |
---|
168 | <calibrationProtocol>Big Oil standard test</calibrationProtocol> |
---|
169 | <parameter uom="m" name="length fine tuning">0.133</parameter> |
---|
170 | <remarks>Well done, Jim</remarks> |
---|
171 | </installationCalibration> |
---|
172 | <basedOnInstalledFiber uidRef="1FO19-120050992-0">Wellbore 1FO19-1 installation 9Jun2004</basedOnInstalledFiber> |
---|
173 | <commonData> |
---|
174 | <comments>common data in this block</comments> |
---|
175 | </commonData> |
---|
176 | <customData/> |
---|
177 | </dtsInstalledSystem> |
---|
178 | </dtsInstalledSystems> |
---|